CEN11CA155

Completed

Cessna R182· N6187S

Date
January 19, 2011
Location
Houston, TX
Conditions
VMC
Record
Published September 25, 2020

Primary finding

Probable cause

The failure of the landing gear to fully extend and lock in the down position due to the inoperative electric pump motor.

Investigator assessment

Analysis narrative

The pilot was returning to the airport after a local maintenance flight. While completing the before-landing checklist, the pilot did not detect an incomplete gear extension. After touchdown, at 70 knots, both main landing gear legs collapsed. The nose gear remained extended during the event and the rear fuselage and left horizontal stabilizer contacted the concrete pavement. The operator's subsequent examination of the hydraulic power pack revealed that the electric pump motor was inoperative. The failure of the power pack before the end of the gear extension cycle would result in a fully extended nose gear and a partial extension of the main landing gear legs.

Source record

Factual narrative

The pilot was returning to the airport after a local maintenance flight. During the before landing cockpit checks the pilot did not detect an incomplete gear extension. After touchdown, at about 70 knots, both main landing gear legs collapsed. The nose gear remained extended during the event and the rear fuselage and left horizontal stabilizer contacted the concrete pavement. The operator's subsequent examination of the hydraulic power pack showed the electric pump motor was inoperative. The failure of the power pack before the end of the gear extension cycle would result in a fully extended nose gear and a partial extension of the main landing gear legs.

Continue research

Find similar accidents

Continue with the strongest shared characteristics.