Back to Search

NTSB investigation record

ERA23LA326

Completed

Hughes 369· N353AH

Date
August 5, 2023
Location
Elberon, VA
Conditions
VMC
Record
Published October 5, 2023

Primary finding

Probable cause

The pilot’s failure to maintain clearance from a power line structure arm, which resulted in main rotor blade contact.

Investigator assessment

Analysis narrative

The purpose of the rotorcraft external load flight was to spray water from the helicopter and wash some outside insulators that were suspended from power line structure arms. During the wash, the crew heard a bang, and the helicopter descended into trees. A Federal Aviation Administration inspector examined the wreckage after the accident and observed substantial damage to the fuselage and rotor blades. The inspector also observed damage to the power line structure arm that was consistent with main rotor blade contact. The inspector did not find evidence of any preimpact mechanical malfunctions or failures of the helicopter, nor did the operator report any. Based on this information, it is likely that the helicopter’s main rotor struck the power line structure while the pilot was maneuvering in close proximity to it.

Continue research

Find similar accidents

Continue with the strongest shared characteristics.