Back to Search

NTSB investigation record

LAX04LA333

Completed

McDonnell Douglas Md900· N9016W

Date
September 8, 2004
Location
Mesa, AZ
Conditions
VMC
Record
Published September 2, 2021

Primary finding

Probable cause

fracture of a Tension-Torsion strap in the anti-torque fan due to progressive fiber failure of the composite strap material from compression and/or transverse shear stresses that occurred with repeated manipulation of the cockpit anti-torque control pedals without the fan operating at full rpm. A factor in the accident was the helicopter manufacturer's inadequate fatigue and load testing on the strap.

Investigator assessment

Analysis narrative

The helicopter experienced a NOTAR (no tail rotor) fan failure during the initial climb from the airport and made a subsequent hard landing. Immediately after takeoff, about 30 to 40 feet above ground level (agl), the helicopter began to vibrate. The pilot lowered the collective to the full down position, and the helicopter touched down about 30 to 40 knots ground speed. Upon touchdown, the pilot had difficulty maintaining directional control and the helicopter slid about 300 feet across terrain. The helicopter's NOTAR anti-torque yaw control system utilizes a transmission driven fan with variable pitch blades to supply air to circulation control slots on the tail boom and a pilot controlled directional jet thruster nozzle. Movement of the anti-torque control pedals changes the fan blade pitch to produce more or less airflow to the circulation control slots and the anti-torque thruster nozzle. As the pedals are displaced from center toward either extreme of travel, the airflow increases or decreases proportionally. A post-accident examination of the NOTAR fan system revealed that one of the thirteen Tension-Torsion (T-T) straps located on the variable-pitch fan assembly had failed. The failed strap had accumulated about 1,694 hours of time in service, though the design safe life for the strap was 2,500 hours of time in service. An examination of the strap revealed that it had fractured as a result of the progressive failure of its reinforcement fibers. This progressive fiber failure gradually degraded the strap's integrity until it could no longer support normal in-service tensile loads. In normal operation, the T-T straps are exposed to tensile loads due to the centrifugal force induced by the blade rotation about the anti-torque fan axis. The straps are additionally exposed to torsional loads about their longitudinal axis as the blade pitch is changed. The point-symmetric locations of the failure areas were consistent with loading that would occur as the strap was twisted with limited centrifugal force loads present; the twisting direction corresponds to an increase in blade pitch. The Safety Board Materials Laboratory performed load analyses of the straps, revealing that when the strap is twisted without the presence of centrifugal force, portions of the fiber reinforced region of the strap are subjected to compression and transverse shear stresses. Furthermore, the compression and transverse shear stresses are highest in the locations where the subject strap failed. When the anti-torque fan is rotated at speeds less than an approximate 75 percent of maximum power, compression, and transverse shear stresses can develop in the straps when the blade pitch is adjusted. Additionally, with no fan rotation (and therefore no centrifugal force) critical buckling strains on the strap's fibers can be achieved by increasing the blade pitch to near the design limits. This could plausibly occur during a preflight inspection when the pilot checks pedal control surface movement prior to starting the engine. All T-T strap load and fatigue tests preformed by the helicopter manufacturer incorporate centrifugal force loads, and therefore, do not test the full load spectrum.

Source record

Factual narrative

HISTORY OF FLIGHT On September 8, 2004, about 1600 mountain standard time, a McDonald Douglas Helicopter MD 900, N9016W, experienced a NOTAR fan failure during the initial climb from the Boeing Heliport, Mesa, Arizona. MD Helicopters, Inc., was operating the helicopter under the provisions of 14 CFR Part 91. The commercial pilot, the sole occupant, was not injured; the helicopter sustained substantial damage. The local company test flight was originating at the time of the accident. Visual meteorological conditions prevailed, and a flight plan had not been filed. In a written statement, the pilot reported that immediately after takeoff, about 30 to 40 feet above ground level (agl), the helicopter began a severe high frequency vibration. The pilot lowered the collective to the full down position, and the helicopter touched down about 30 to 40 knots ground speed. Upon touchdown, the pilot had difficulty maintaining direction control. The helicopter slid about 300 feet across terrain, coming to rest 4 feet off the departure end of the runway. After egressing the helicopter, the pilot found three complete NOTAR fan blades scattered on the runway surface. The disassembly of the NOTAR fan system revealed that a Tension-Torsion (TT) strap on the fan assembly had been compromised. AIRCRAFT INFORMATION The helicopter was a 1995 McDonald Douglas Helicopter MD900, serial number 900-00016. A review of the helicopter's maintenance information revealed that the airframe had undergone an annual inspection on April 30, 2004. At the last 50-hour inspection the helicopter had accumulated a total time of 1,686.96 hours. At the time of the accident the helicopter had accumulated a total time of 1693.2 hours, with the engine hours at 1,241.39 and 2202.74. NOTAR Anti-Torque system. According to MD Helicopters, the MD900 anti-torque system, entitled NOTAR (no tail rotor), consists of an enclosed variable-pitch fan that is controlled by the main transmission. The fan produces a low pressure and high volume of ambient air, which in turn pressurizes the composite tail boom. As low pressure air is directed through two circulation control slots located in the tail boom, the main rotor downwash follows that expelled air with the contours of the boom. This phenomenon of creating lateral lift to counteract main rotor torque provides a majority of the anti-torque force required while in a hover configuration, and is referred to as the "Coanda Effect." Additional anti-torque and directional controllability is accomplished by a rotating thruster affixed to the end of the tail boom, which is manipulated by the pilot via the use of anti-torque pedals. According to McDonnel-Douglas Helicopter, Inc. (MDHI) engineers, during hover the Coanda effect produces approximately 70 percent of the helicopter's anti-torque force, while the thruster produces the remaining 30 percent. During normal cruise, two parallel vertical stabilizers provide most of the anti-torque, while the thruster is the primary manipulator of directional control. Tension-Torsion Straps The variable-pitch rotating fan assembly is comprised of thirteen T-T straps, which extend radially from the center spline. The straps are constructed from continuous-wound Kevlar fibers that are wrapped around corrosion-resistant steel spools at both ends of the strap. The spools have circular flanges at each end of a cylindrical spindle, and the spindles have bolt holes in the centers where the strap is attached to its respective surfaces. After manufacture, the strap is cast in a polyurethane material, creating a fiber reinforced region with a protective outer coating of polyurethane. The straps measure 5.9 inches in length, 0.86 inches in width, 0.47 inches in thickness, and are rectangular in shape with semicircular ends. A similarly shaped recess is impressed in the middle of the strap with the ends adjacent to the most inner part of the metal spools. Inside the recess, at both ends, there is a cutout area of material, akin to a hole-punch shape. The straps' outer spools are connected the blade assemblies, and the inner spools adjoin the center spline assembly. The blade assemblies of the anti-torque fan have a variable pitch, which is controlled through a sliding pitch change plate that is attached to arms on the blade assemblies. As the pitch changes, the blade assemblies rotate within openings in the inner and outer rims of the fan hub, loading the straps in torsion about their longitudinal axes. Centrifugal forces are produced by the fan blade assemblies rotating about the center of the anti-torque fan assembly, resulting in the straps incurring a load in tension during fan operation. TESTS AND RESEARCH Under the auspice of a Federal Aviation Administration (FAA) inspector, 10 of the 12 intact T-T straps from the accident anti-torque fan assembly were spring rate tested in tension and torsion loading conditions at the T-T strap manufacturer, Lord Corporation, facilities. One test subjected the straps to tensile loading where the pull direction was aligned with the longitudinal axis of the strap. The other test was under angular displacement (torsional loading) with no tensile load, where the strap was twisted about the longitudinal axis. As documented in manufacturing procedures, similar tests are conducted as proof tests on each newly manufactured strap. The manufacturer provided data from the original proof tests for the two most recently manufactured straps that were tested. The engineering drawings specify a minimum tensile stiffness for the strap as well as a maximum torsional stiffness with zero tensile loads. All 10 of the tested straps were able to support the maximum tensile loads during the tensile tests and had tensile stiffnesses that exceeded the minimum value specified in the engineering drawings. A direct comparison of the post accident stiffness to the original proof test values was not possible since a different preload procedure was used at the time of manufacturing versus post accident testing. All 10 of the tested straps also were able to support the maximum angular displacement during the torsion tests and had torsional stiffnesses below the maximum value specified in the engineering drawings. Upon the completion of the aforementioned testing, the straps were forwarded to the Safety Board Materials Laboratory for additional examinations. Fractured Tension-Torsion Strap The fractured T-T strap, part number 500N5311-5, had accumulated about 1,694 hours of time in service. The design safe life for the straps was 2,500 hours of time in service. The failed strap, marked serial number LK0959, was fractured at the inner end of the strap, and the respective spool was separated from the remainder of the strap. Fibers extended from each leg of the strap, and the exposed ends of the fibers were frayed. Most of the fibers that had wrapped around the spool were pulled out from around the spool, creating a void between the metal spindle of the spool and the layer of polyurethane on the exterior surface of the strap assembly. A detailed examination of the fracture revealed that there were two areas where multiple fibers had fractured at a similar location. The two relatively flat fracture areas were oriented in a plane perpendicular to the fiber direction. These flat fracture areas were located about 1 inch inboard from the inner end of the strap, where the fibers closest to the spool center intersect the spool flange. X-ray radiographs and polished cross-sections of the straps revealed that cracking and fiber kinking was prevalent in the straps. Transverse cracks were observed in the x-ray radiograph of one of the intact straps. Longitudinal cracks were observed in the x-ray radiographs of half of the intact straps and in the fractured strap. As observed in polished cross-sections, both longitudinal and transverse c

Continue research

Find similar accidents

Continue with the strongest shared characteristics.