Primary finding
Probable cause
a fatigue failure of the torsion-tension bar pin due to fretting corrosion. A factor in this accident was an inadequate quality of material utilized in the manufacture of the pin.
NTSB investigation record
Hiller Uh-12E· N161HA
Primary finding
a fatigue failure of the torsion-tension bar pin due to fretting corrosion. A factor in this accident was an inadequate quality of material utilized in the manufacture of the pin.